OMNI SCAN F/X-B7.5 Fixed Cargo X-Ray System
Application It has one 7.5/4MeV Dual-energy MIB-7.5/4 Betatron radiation source. It is designed for effective rapid non-intrusive inspection of 10, 20, 40ft containers or cargo trucks and others such as refrigerator trucks, minibus, special vehicles and closures like tires, vehicle doors, oil tanks and layered walls. 
|
|
Physical Dimensions
- 48 m (L)×16m (W) Scanning Tunnel built of concrete for Fixed Container Scanning System
- 55 m (L)×20m (W) The system footprint including Scanning Tunnel, Operation Control Room and Workstation Room.
|
System Dimensions
- Overall length: 4m (Gantry rails, 42m long)
- Overall width: 12m
- Overall height: 5.6m
|
|
Technical Specifications
X-RAY SYSTEM
- Source 7.5/4MeV Betatron
- Detector array 5mm detector elements, scintillating crystal and photo diodes with electronics designed for extremely high signal-to-noise ratio.
PERFORMANCE
- Throughput ≥30 trucks per hour
- Resolution (Single wire diameter in air) ≤ 1.2mm no fenced plate
- Penetration max. ≥ 350mm steel
- Contrast Sensitivity ≤ 2%, 2mm thickness of steel disk behind of a fenced plate of 100mm thickness
- IQI ≤ 4%, 4mm diameter wire behind 100mm of steel
SCAN DIMENSIONS
- Ambient scanning 4.8m (H)x2.8m (W)
- Maximum scan height ≥4.9m
- Source tire cutoff ≤0.35m above the ground
ENVIRONMENT
- Operating temperature -15˚C(-59˚F)to +40˚C(+104˚F)
- Storage -30˚C(-22˚F)to +55˚C(+131˚F)
- Relative Humidity 0% to 96%, at an ambient external temperature of +40˚C
RADIATION SAFETY
- Standards : Meets applicable compliance standards set forth in U.S. Code of Federal regulations 21CFR1020.40 for Cabinet X-ray systems
- Meets applicable U.S., the European Union regulatory requirements
ICRP Publication 60
- Maximum Dose Rate on the system boundary ≤ 1µSv/hr
- Dose Rate for Cargo ≤ 10µSv/Scan at any region of cargo
- Dose Rate for Operator < 5mSv/yr
- Dose Rate for Public < 0.5mSV/yr
|
OPERATION DUTY (Not included time for regular maintenance schedule)
- 24/24 hour working
- 95% availability to work per year
OPERATOR CONTROL CENTER
- Five (5) workstations – one for data acquisition and two for image analyzing (more to be provided)
- Computers
- 22’’ LCD Monitors
- Image Archiving (more than 100,000 images)
- Hard Disk: 5TB
- A4 color laser printer
- DVD (RW)
- UPS
IMAGE ANALYSIS
- Black/While Image, Bright and Contrast, Pseudo Color, Sharpen, Zoom, Edge Enhancement, Inverted Image, Histogram equalization, Mark and Annotation (up to 300 characters), Ruler (Object measuring), Density Alarm, Image Comparison (side-by-side), Reversed Image (Mirroring), Image-format conversion (jpeg, tiff, bmp), Flipping….
OTHERS
- Automatic vehicle license plate and container number recognition (mounted on truck)
- Wireless communication for image transfer, diagnostics, and remote viewing
- Remote image analysis workstation
- Wireless monitoring, command, and control system
- Emergency Backup System
- Radiation and neutron detection
- Availability to link with Electronic Truck Scales
|
|