OMNI SCAN F/X-B7.5 Fixed Cargo X-Ray System

Overview

Application
It has one 7.5/4MeV Dual-energy MIB-7.5/4 Betatron radiation source. It is designed for effective rapid non-intrusive inspection of 10, 20, 40ft containers or cargo trucks and others such as refrigerator trucks, minibus, special vehicles and closures like tires, vehicle doors, oil tanks and layered walls.

 

Physical Dimensions

  • 48 m (L)×16m (W)     Scanning Tunnel built of concrete for Fixed Container Scanning System
  • 55 m (L)×20m (W)  The system footprint including Scanning Tunnel, Operation Control Room and Workstation Room.

 

System Dimensions

  • Overall length: 4m (Gantry rails, 42m long)
  • Overall width: 12m
  • Overall height: 5.6m

 

Technical Details

 


Technical Specifications

X-RAY SYSTEM

  • Source    7.5/4MeV Betatron
  • Detector array    5mm detector elements, scintillating crystal and photo diodes with electronics designed for extremely high signal-to-noise ratio.
PERFORMANCE
  • Throughput    ≥30 trucks per hour
  • Resolution (Single wire diameter in air)    ≤ 1.2mm no fenced plate
  • Penetration max.    ≥ 350mm steel
  • Contrast Sensitivity    ≤ 2%, 2mm thickness of steel disk behind of a fenced plate of 100mm thickness
  • IQI    ≤ 4%, 4mm diameter wire behind 100mm of steel
SCAN DIMENSIONS
  • Ambient scanning    4.8m (H)x2.8m (W)
  • Maximum scan height    ≥4.9m
  • Source tire cutoff    ≤0.35m above the ground

 

ENVIRONMENT

  • Operating temperature    -15˚C(-59˚F)to  +40˚C(+104˚F)
  • Storage            -30˚C(-22˚F)to  +55˚C(+131˚F)
  • Relative Humidity                  0% to 96%, at an ambient external temperature of +40˚C

RADIATION SAFETY

 

  • Standards : Meets applicable compliance standards set forth in U.S. Code of Federal regulations 21CFR1020.40 for Cabinet X-ray systems
  • Meets applicable U.S., the European Union regulatory requirements
    ICRP Publication 60
  • Maximum Dose Rate on the system boundary    ≤ 1µSv/hr
  • Dose Rate for Cargo    ≤ 10µSv/Scan at any region of cargo
  • Dose Rate for Operator    < 5mSv/yr
  • Dose Rate for Public    < 0.5mSV/yr

 




 

 

 

OPERATION DUTY (Not included time for regular maintenance schedule)

  • 24/24 hour working
  • 95% availability to work per year


OPERATOR CONTROL CENTER

  • Five (5) workstations – one for data acquisition and two for image analyzing (more to be provided)
  • Computers
  • 22’’ LCD Monitors
  • Image Archiving (more than 100,000 images)
  • Hard Disk: 5TB
  • A4 color laser printer
  • DVD (RW)
  • UPS

IMAGE  ANALYSIS

  • Black/While Image, Bright and Contrast, Pseudo Color, Sharpen, Zoom, Edge Enhancement, Inverted Image, Histogram equalization, Mark and Annotation (up to 300 characters), Ruler (Object measuring), Density Alarm, Image Comparison (side-by-side), Reversed Image (Mirroring), Image-format conversion (jpeg, tiff, bmp), Flipping….

OTHERS

  • Automatic vehicle license plate and container number recognition (mounted on truck)
  • Wireless communication for image transfer, diagnostics, and remote viewing
  • Remote image analysis workstation
  • Wireless monitoring, command, and control system
  • Emergency Backup System
  • Radiation and neutron detection
  • Availability to link with Electronic Truck Scales